Call 08046036121 86% Response Rate

our range

Detuned Reactor

Leading Wholesale Trader of detuned filter reactor and detuned reactor from Mumbai.
  • Detuned Filter Reactor
  • Detuned Filter Reactor
  • Detuned Filter Reactor
Detuned Filter Reactor

Detuned Filter Reactor

Rs 7,000  / PieceGet Best Price

Product Brochure

Max Ambient Temperature50 Degree C
Temperature SensorYes
Rated Frequency50 Hz
Operating ModeContinuous
Winding MaterialAl Wound
Rated Voltage415 V / 440 V
Protection ClassIP00, Indoor Operation
Duty Cycle100%
Maximum Altitude1000 m
Reactant Factor5.67%, 7% and 14%
Min Ambient Temperature5 Degree C
Allowed Temperature Rise115 Degree C Utilized according to Insulation Class H
Insulation ClassT50 / H
Type of CoolingNatural Convection
Matching up with the ever increasing requirements of the customers, we are engaged in providing Detuned Reactor.

Product Detail:
  • Design Three Phase
  • Iron Core Reactor with Air Gaps
  • Poly Gap (R) Core Design Impregnation
  • Complete Unit Vacuum – Overpressure Impregnated with Temperature Class H Resin and cured in an Oven Harmonic Load Design Voltage Distortion Based on UN: u1 = 106 % u3 = 0.5 % u5 = 3.5 % u7 = 3.5 % 

View Complete details

get quote request a call back
  • Detuned Reactor
  • Detuned Reactor
  • Detuned Reactor
Detuned Reactor

Detuned Reactor

Rs 7,000  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Voltage415 V / 440 V
TypeTower Reactor
Capacity0.5kw~500kw
Rated Frequency50 Hz
Reactance Factor5.67%, 7% and 14%
Ambient TemperatureMax 5 deg C
We are offering Detuned Reactor.These products are processed with utmost care under the guidance of skilled professionals from the respective field. 

View Complete details

get quote request a call back
  • Detuned Reactor
  • Detuned Reactor
  • Detuned Reactor
Detuned Reactor

Detuned Reactor

Rs 6,200  / PieceGet Best Price

Product Brochure

Reactance Factor5.67%, 7% and 14% (0.2% on request)
DesignThree Phase, Iron Core Reactor with Air Gaps, Poly Gap (R) Core Design
Duty Cycle100%
Max Ambient Temperature50 deg C
Operating ModeContinuous
Min Ambient Temperature5 deg C
Rated Voltage415 V / 440 V
Rated Frequency50 Hz
Other Details:
  • Impregnation: Complete Unit Vacuum – Overpressure Impregnated with Temperature Class H Resin and cured in an Oven
  • Harmonic Load Design:  Voltage Distortion Based on UN : u1 = 106 % u3 = 0.5 % u5 = 3.5 % u7 = 3.5 %

Standard:
  • IEC Standard: IEC 60076-6
  • IS Standard: IS-5553-1990 Part 5
  • Winding Material: Al wound
  • Winding Insulation: Double Layer Fibre-Glass
  • Termination: Aluminum / Copper Lugs
  • Noise Level: Less than 60 dB at rated load at 1 meter distance
  • Linearity: 180 %

View Complete details